WEKO3
アイテム
{"_buckets": {"deposit": "a8ac849d-3768-4a25-ba00-90796472c5e0"}, "_deposit": {"created_by": 11, "id": "187", "owners": [11], "pid": {"revision_id": 0, "type": "depid", "value": "187"}, "status": "published"}, "_oai": {"id": "oai:kagawa-u.repo.nii.ac.jp:00000187", "sets": ["40"]}, "author_link": ["398"], "item_10006_date_granted_11": {"attribute_name": "学位授与年月日", "attribute_value_mlt": [{"subitem_dategranted": "2013-06-25"}]}, "item_10006_degree_grantor_9": {"attribute_name": "学位授与機関", "attribute_value_mlt": [{"subitem_degreegrantor": [{"subitem_degreegrantor_language": "ja", "subitem_degreegrantor_name": "香川大学"}, {"subitem_degreegrantor_language": "en", "subitem_degreegrantor_name": "Kagawa University"}], "subitem_degreegrantor_identifier": [{"subitem_degreegrantor_identifier_name": "16201", "subitem_degreegrantor_identifier_scheme": "kakenhi"}]}]}, "item_10006_degree_name_8": {"attribute_name": "学位名", "attribute_value_mlt": [{"subitem_degreename": "博士(医学)", "subitem_degreename_language": "ja"}]}, "item_10006_description_7": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "OBJECTIVES\nInfrared thoracoscopy is a new method of identifying lung intersegmental borders. This study compared the efficacy of 2- and 1-wavelength infrared thoracoscopy.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}, {"subitem_description": "METHODS\nA total of 30 consecutive patients who underwent segmentectomy were evaluated by these methods (2-wavelength method, 10 patients; 1-wavelength method, 20 patients). We ligated the dominant pulmonary artery and then observed the lung using an infrared thoracoscope after indocyanine green (ICG) intravenous injection. The 2-wavelength infrared thoracoscope irradiation and detection were conducted at 940 and 805 nm, respectively, and the images were projected based on the difference of the two reflected wavelengths. ICG absorbs 805 nm wavelength light, and the ICG distribution area appears blue against a white background. On the other hand, the 1-wavelength infrared thoracoscope irradiation and detection were conducted at 780 and 830 nm, respectively. The area stained with ICG shows fluorescence.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}, {"subitem_description": "RESULTS\nIn the 2-wavelength method, 3.0 mg/kg of ICG was administered, and a well-defined white-to-blue border was observed in 9 of 10 patients. The staining duration was 220 (interquartile range, 187–251) s. In the 1-wavelength method, 0.5 mg/kg of ICG was administered, and a well-defined border between areas with or without fluorescence was observed in 19 of 20 patients. The staining duration was 370 (interquartile range, 296–440) s, which was significantly longer than the staining duration with the 2-wavelength method (P = 0.0001).", "subitem_description_language": "en", "subitem_description_type": "Abstract"}, {"subitem_description": "CONCLUSIONS\nInfrared thoracoscopy is useful for detection of intersegmental borders. The dose of ICG for the 1-wavelength method was less than that for 2-wavelength method, and the duration of staining was longer.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_10006_dissertation_number_12": {"attribute_name": "学位授与番号", "attribute_value_mlt": [{"subitem_dissertationnumber": "甲第572号"}]}, "item_10006_relation_15": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1093/ejcts/ezt168", "subitem_relation_type_select": "DOI"}}]}, "item_10006_relation_22": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "23616482", "subitem_relation_type_select": "PMID"}}]}, "item_10006_text_30": {"attribute_name": "KEID", "attribute_value_mlt": [{"subitem_text_value": "27455"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorAffiliations": [{"affiliationNameIdentifiers": [{"affiliationNameIdentifier": "", "affiliationNameIdentifierScheme": "ISNI", "affiliationNameIdentifierURI": "http://www.isni.org/isni/"}], "affiliationNames": [{"affiliationName": "", "affiliationNameLang": "ja"}]}], "creatorNames": [{"creatorName": "Kasai, Yoshitaka", "creatorNameLang": "en"}, {"creatorName": "笠井, 由隆", "creatorNameLang": "ja"}, {"creatorName": "カサイ, ヨシタカ", "creatorNameLang": "ja-Kana"}], "familyNames": [{"familyName": "Kasai", "familyNameLang": "en"}, {"familyName": "笠井", "familyNameLang": "ja"}, {"familyName": "カサイ", "familyNameLang": "ja-Kana"}], "givenNames": [{"givenName": "Yoshitaka", "givenNameLang": "en"}, {"givenName": "由隆", "givenNameLang": "ja"}, {"givenName": "ヨシタカ", "givenNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "398", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "9000241509344 ", "nameIdentifierScheme": "CiNii ID", "nameIdentifierURI": "http://ci.nii.ac.jp/nrid/9000241509344 "}, {"nameIdentifier": "40610085", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=40610085"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-10-21"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Med_A572_abstract.pdf", "filesize": [{"value": "346.6 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 346600.0, "url": {"label": "内容の要旨", "objectType": "abstract", "url": "https://kagawa-u.repo.nii.ac.jp/record/187/files/Med_A572_abstract.pdf"}, "version_id": "36468c5a-932b-410f-85eb-aebd64637acb"}, {"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-10-21"}], "displaytype": "detail", "download_preview_message": "", "file_order": 1, "filename": "Med_A572_rusult.pdf", "filesize": [{"value": "392.8 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 392800.0, "url": {"label": "審査の結果の要旨", "objectType": "other", "url": "https://kagawa-u.repo.nii.ac.jp/record/187/files/Med_A572_rusult.pdf"}, "version_id": "5f41320a-462c-4d38-a439-60725509bb76"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Infrared thoracoscopy", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Indocyanine green", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Lung segmentectomy", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "doctoral thesis", "resourceuri": "http://purl.org/coar/resource_type/c_db06"}]}, "item_title": "Clinical trial of new methods for identifying lung intersegmental borders using infrared thoracoscopy with indocyanine green: comparative analysis of 2- and 1-wavelength methods", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Clinical trial of new methods for identifying lung intersegmental borders using infrared thoracoscopy with indocyanine green: comparative analysis of 2- and 1-wavelength methods", "subitem_title_language": "en"}]}, "item_type_id": "10006", "owner": "11", "path": ["40"], "permalink_uri": "https://kagawa-u.repo.nii.ac.jp/records/187", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2013-06-25"}, "publish_date": "2013-06-25", "publish_status": "0", "recid": "187", "relation": {}, "relation_version_is_last": true, "title": ["Clinical trial of new methods for identifying lung intersegmental borders using infrared thoracoscopy with indocyanine green: comparative analysis of 2- and 1-wavelength methods"], "weko_shared_id": -1}
Clinical trial of new methods for identifying lung intersegmental borders using infrared thoracoscopy with indocyanine green: comparative analysis of 2- and 1-wavelength methods
https://kagawa-u.repo.nii.ac.jp/records/187
https://kagawa-u.repo.nii.ac.jp/records/18768d9c062-000e-4fc5-90e5-bcad9ba6a2a6
名前 / ファイル | ライセンス | アクション |
---|---|---|
内容の要旨 (346.6 kB)
|
|
|
審査の結果の要旨 (392.8 kB)
|
|
Item type | 学位論文 / Thesis or Dissertation(1) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2013-06-25 | |||||||||||
タイトル | ||||||||||||
言語 | en | |||||||||||
タイトル | Clinical trial of new methods for identifying lung intersegmental borders using infrared thoracoscopy with indocyanine green: comparative analysis of 2- and 1-wavelength methods | |||||||||||
言語 | ||||||||||||
言語 | eng | |||||||||||
資源タイプ | ||||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_db06 | |||||||||||
資源タイプ | doctoral thesis | |||||||||||
著者 |
笠井, 由隆
× 笠井, 由隆
WEKO
398
|
|||||||||||
抄録 | ||||||||||||
内容記述タイプ | Abstract | |||||||||||
内容記述 | OBJECTIVES Infrared thoracoscopy is a new method of identifying lung intersegmental borders. This study compared the efficacy of 2- and 1-wavelength infrared thoracoscopy. |
|||||||||||
言語 | en | |||||||||||
抄録 | ||||||||||||
内容記述タイプ | Abstract | |||||||||||
内容記述 | METHODS A total of 30 consecutive patients who underwent segmentectomy were evaluated by these methods (2-wavelength method, 10 patients; 1-wavelength method, 20 patients). We ligated the dominant pulmonary artery and then observed the lung using an infrared thoracoscope after indocyanine green (ICG) intravenous injection. The 2-wavelength infrared thoracoscope irradiation and detection were conducted at 940 and 805 nm, respectively, and the images were projected based on the difference of the two reflected wavelengths. ICG absorbs 805 nm wavelength light, and the ICG distribution area appears blue against a white background. On the other hand, the 1-wavelength infrared thoracoscope irradiation and detection were conducted at 780 and 830 nm, respectively. The area stained with ICG shows fluorescence. |
|||||||||||
言語 | en | |||||||||||
抄録 | ||||||||||||
内容記述タイプ | Abstract | |||||||||||
内容記述 | RESULTS In the 2-wavelength method, 3.0 mg/kg of ICG was administered, and a well-defined white-to-blue border was observed in 9 of 10 patients. The staining duration was 220 (interquartile range, 187–251) s. In the 1-wavelength method, 0.5 mg/kg of ICG was administered, and a well-defined border between areas with or without fluorescence was observed in 19 of 20 patients. The staining duration was 370 (interquartile range, 296–440) s, which was significantly longer than the staining duration with the 2-wavelength method (P = 0.0001). |
|||||||||||
言語 | en | |||||||||||
抄録 | ||||||||||||
内容記述タイプ | Abstract | |||||||||||
内容記述 | CONCLUSIONS Infrared thoracoscopy is useful for detection of intersegmental borders. The dose of ICG for the 1-wavelength method was less than that for 2-wavelength method, and the duration of staining was longer. |
|||||||||||
言語 | en | |||||||||||
学位名 | ||||||||||||
言語 | ja | |||||||||||
学位名 | 博士(医学) | |||||||||||
学位授与機関 | ||||||||||||
学位授与機関識別子Scheme | kakenhi | |||||||||||
学位授与機関識別子 | 16201 | |||||||||||
言語 | ja | |||||||||||
学位授与機関名 | 香川大学 | |||||||||||
言語 | en | |||||||||||
学位授与機関名 | Kagawa University | |||||||||||
学位授与年月日 | ||||||||||||
学位授与年月日 | 2013-06-25 | |||||||||||
学位授与番号 | ||||||||||||
学位授与番号 | 甲第572号 | |||||||||||
PubMed番号 | ||||||||||||
識別子タイプ | PMID | |||||||||||
関連識別子 | 23616482 | |||||||||||
関連サイト | ||||||||||||
関連タイプ | isVersionOf | |||||||||||
識別子タイプ | DOI | |||||||||||
関連識別子 | https://doi.org/10.1093/ejcts/ezt168 | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | Infrared thoracoscopy | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | Indocyanine green | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | Lung segmentectomy | |||||||||||
KEID | ||||||||||||
27455 |