{"created":"2023-05-15T09:41:09.480803+00:00","id":186,"links":{},"metadata":{"_buckets":{"deposit":"5eb65d90-9efb-455f-8202-628c55193062"},"_deposit":{"created_by":11,"id":"186","owners":[11],"pid":{"revision_id":0,"type":"depid","value":"186"},"status":"published"},"_oai":{"id":"oai:kagawa-u.repo.nii.ac.jp:00000186","sets":["13:40"]},"author_link":["201"],"item_10006_date_granted_11":{"attribute_name":"学位授与年月日","attribute_value_mlt":[{"subitem_dategranted":"2013-04-17"}]},"item_10006_degree_grantor_9":{"attribute_name":"学位授与機関","attribute_value_mlt":[{"subitem_degreegrantor":[{"subitem_degreegrantor_language":"ja","subitem_degreegrantor_name":"香川大学"},{"subitem_degreegrantor_language":"en","subitem_degreegrantor_name":"Kagawa University"}],"subitem_degreegrantor_identifier":[{"subitem_degreegrantor_identifier_name":"16201","subitem_degreegrantor_identifier_scheme":"kakenhi"}]}]},"item_10006_degree_name_8":{"attribute_name":"学位名","attribute_value_mlt":[{"subitem_degreename":"博士(医学)","subitem_degreename_language":"ja"}]},"item_10006_description_7":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Purpose \nTo evaluate the effectiveness of using a noncontact tonometer (NCT) versus a rebound tonometer (ICare) when measuring the intraocular pressure (IOP) in healthy children.","subitem_description_language":"en","subitem_description_type":"Abstract"},{"subitem_description":"Design \nProspective observational study.","subitem_description_language":"en","subitem_description_type":"Abstract"},{"subitem_description":"Methods \nA total of 180 (96 males and 84 females) healthy children, aged 6 months to 15 years, were recruited. IOPs were measured using both the NCT and ICare devices in the absence of anesthesia. A successful outcome was defined as the measurement of the IOP in both eyes. The McNemar test for comparing correlated proportions was used to analyze the ICare and NCT data.","subitem_description_language":"en","subitem_description_type":"Abstract"},{"subitem_description":"Results \nAlthough the IOP was successfully measured in 160 children (88.9%) when using ICare, we were only able to successfully measure 130 children (72.2%) when using NCT. Below the age of 6 years, measurement of the IOP using ICare was better tolerated as compared with the NCT (McNemar test; P<0.001). The mean differences (95% limits of agreement) for the IOP readings between ICare and NCT in right and left eyes were 0.90±6.40 and 1.18±6.19 mm Hg, respectively.","subitem_description_language":"en","subitem_description_type":"Abstract"},{"subitem_description":"Conclusions \nIOP measurements performed using ICare are better tolerated in the pediatric population, as compared with measurements using NCT, especially in children below the age of 6 years.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10006_dissertation_number_12":{"attribute_name":"学位授与番号","attribute_value_mlt":[{"subitem_dissertationnumber":"乙第264号"}]},"item_10006_relation_15":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1097/IJG.0b013e3181d12dc4","subitem_relation_type_select":"DOI"}}]},"item_10006_relation_22":{"attribute_name":"PubMed番号","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"20179620","subitem_relation_type_select":"PMID"}}]},"item_10006_text_30":{"attribute_name":"KEID","attribute_value_mlt":[{"subitem_text_value":"27447"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"","affiliationNameIdentifierScheme":"ISNI","affiliationNameIdentifierURI":"http://www.isni.org/isni/"}],"affiliationNames":[{"affiliationName":"","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"Kageyama, Mitsuyo","creatorNameLang":"en"},{"creatorName":"蔭山, 光代","creatorNameLang":"ja"},{"creatorName":"カゲヤマ, ミツヨ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-10-21"}],"displaytype":"detail","filename":"Med_B264_abstract.pdf","filesize":[{"value":"267.6 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"内容の要旨","objectType":"abstract","url":"https://kagawa-u.repo.nii.ac.jp/record/186/files/Med_B264_abstract.pdf"},"version_id":"a5fcc508-d589-46ee-8551-834b3d6033b3"},{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-10-21"}],"displaytype":"detail","filename":"Med_B264_result.pdf","filesize":[{"value":"347.1 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"審査の結果の要旨","objectType":"other","url":"https://kagawa-u.repo.nii.ac.jp/record/186/files/Med_B264_result.pdf"},"version_id":"2380e61a-860a-4f59-b912-44a9410458d4"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"doctoral thesis","resourceuri":"http://purl.org/coar/resource_type/c_db06"}]},"item_title":"Comparison of ICare rebound tonometer with noncontact tonometer in healthy children","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Comparison of ICare rebound tonometer with noncontact tonometer in healthy children","subitem_title_language":"en"}]},"item_type_id":"10006","owner":"11","path":["40"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2013-04-17"},"publish_date":"2013-04-17","publish_status":"0","recid":"186","relation_version_is_last":true,"title":["Comparison of ICare rebound tonometer with noncontact tonometer in healthy children"],"weko_creator_id":"11","weko_shared_id":-1},"updated":"2024-02-05T01:40:42.397041+00:00"}