{"created":"2023-05-15T09:41:18.172864+00:00","id":395,"links":{},"metadata":{"_buckets":{"deposit":"e53e261c-a71b-4c5f-ab23-548dc6949e5b"},"_deposit":{"created_by":11,"id":"395","owners":[11],"pid":{"revision_id":0,"type":"depid","value":"395"},"status":"published"},"_oai":{"id":"oai:kagawa-u.repo.nii.ac.jp:00000395","sets":["13:40"]},"author_link":["2415"],"item_10006_date_granted_11":{"attribute_name":"学位授与年月日","attribute_value_mlt":[{"subitem_dategranted":"2016-02-17"}]},"item_10006_degree_grantor_9":{"attribute_name":"学位授与機関","attribute_value_mlt":[{"subitem_degreegrantor":[{"subitem_degreegrantor_language":"ja","subitem_degreegrantor_name":"香川大学"},{"subitem_degreegrantor_language":"en","subitem_degreegrantor_name":"Kagawa University"}],"subitem_degreegrantor_identifier":[{"subitem_degreegrantor_identifier_name":"16201","subitem_degreegrantor_identifier_scheme":"kakenhi"}]}]},"item_10006_degree_name_8":{"attribute_name":"学位名","attribute_value_mlt":[{"subitem_degreename":"博士(医学)","subitem_degreename_language":"ja"}]},"item_10006_description_7":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Objective: The aim of the study is to evaluate the usefulness of multislice computed tomography (MSCT) using multiplanar reconstruction (MPR) in obtaining preoperative information on the ossicular lesions of middle ear diseases by comparing the ossicular findings of MPR images with the operative findings.","subitem_description_language":"en","subitem_description_type":"Abstract"},{"subitem_description":"Methods: Sixty-two ears and 10 ears with preoperative middle ear diseases underwent 4- and 64-detector row CT of the temporal bone in Kagawa University Hospital, respectively. MPR images of three ossicles were created at the planes parallel to the long axis of ossicles.","subitem_description_language":"en","subitem_description_type":"Abstract"},{"subitem_description":"Results: The findings of the three ossicles in MPR images were compatible with their operative findings in approximately 91% of 72 ears with various middle ear diseases. There was no significant difference in the coincidence rate of both findings between 4- and 64-detector row CT scanners. The ears with no soft tissue shadows around the ossicles had the coincidence rate of 96-100% in each ossicular part, whereas the coincidence rate was lower in the ears with soft tissue shadows around the ossicles.","subitem_description_language":"en","subitem_description_type":"Abstract"},{"subitem_description":"Conclusion: MPR imagings of the ossicles provide accurate preoperative information on the ossicular lesions in middle ear diseases. The 4-detector CT is still a useful device for imaging of the ossicles.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10006_dissertation_number_12":{"attribute_name":"学位授与番号","attribute_value_mlt":[{"subitem_dissertationnumber":"乙第275号"}]},"item_10006_relation_15":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1016/j.anl.2015.08.007","subitem_relation_type_select":"DOI"}},{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://dl.ndl.go.jp/pid/11337631","subitem_relation_type_select":"URI"}}]},"item_10006_relation_22":{"attribute_name":"PubMed番号","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"26386497","subitem_relation_type_select":"PMID"}}]},"item_10006_relation_28":{"attribute_name":"論文ID(NAID)","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"500001356654","subitem_relation_type_select":"NAID"}}]},"item_10006_rights_13":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.","subitem_rights_language":"en"},{"subitem_rights":"この博士論文の本文については、次のエルゼビアの著作権ポリシーの規定により公開しています。「博士論文の場合は、エンバーゴ期間に関係なく機関リポジトリに出版社版を公開することができます。」","subitem_rights_language":"ja"},{"subitem_rights":"The text of this doctoral dissertation is published according to the following Elsevier copyright policy. \"In the case of doctoral dissertations, publishers can be published in institutional repositories regardless of the Embargo period.\"","subitem_rights_language":"en"}]},"item_10006_text_30":{"attribute_name":"KEID","attribute_value_mlt":[{"subitem_text_value":"28759"}]},"item_10006_version_type_18":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_fa2ee174bc00049f","subitem_version_type":"P"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":""}],"affiliationNames":[{"affiliationName":""}]}],"creatorNames":[{"creatorName":"Fujiwara, Seiko","creatorNameLang":"en"},{"creatorName":"藤原, 聖子","creatorNameLang":"ja"},{"creatorName":"フジワラ, セイコ","creatorNameLang":"ja-Kana"}],"familyNames":[{},{},{}],"givenNames":[{},{},{}],"nameIdentifiers":[{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-11-09"}],"displaytype":"detail","filename":"Med_B275.pdf","filesize":[{"value":"4.8 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"本文","objectType":"fulltext","url":"https://kagawa-u.repo.nii.ac.jp/record/395/files/Med_B275.pdf"},"version_id":"64e2ae0c-75df-4bce-b555-cc7b53fa525b"},{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-11-09"}],"displaytype":"detail","filename":"Med_B275_abstract.pdf","filesize":[{"value":"74.4 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"内容の要旨","objectType":"abstract","url":"https://kagawa-u.repo.nii.ac.jp/record/395/files/Med_B275_abstract.pdf"},"version_id":"44830aea-801f-4088-9bc8-e512b7c892f0"},{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-11-09"}],"displaytype":"detail","filename":"Med_B275_result.pdf","filesize":[{"value":"547.2 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"審査の結果の要旨","objectType":"other","url":"https://kagawa-u.repo.nii.ac.jp/record/395/files/Med_B275_result.pdf"},"version_id":"903b34de-335c-431c-839d-a78e2a0b714f"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Multiscan CT","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Multiplanar reconstruction image","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Middle ear diseases","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Auditory ossicular lesion","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Surgical findings","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"doctoral thesis","resourceuri":"http://purl.org/coar/resource_type/c_db06"}]},"item_title":"Usefulness of multislice-CT using multiplanar reconstruction in the preoperative assessment of the ossicular lesions in the middle ear diseases","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Usefulness of multislice-CT using multiplanar reconstruction in the preoperative assessment of the ossicular lesions in the middle ear diseases","subitem_title_language":"en"}]},"item_type_id":"10006","owner":"11","path":["40"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2019-07-22"},"publish_date":"2019-07-22","publish_status":"0","recid":"395","relation_version_is_last":true,"title":["Usefulness of multislice-CT using multiplanar reconstruction in the preoperative assessment of the ossicular lesions in the middle ear diseases"],"weko_creator_id":"11","weko_shared_id":-1},"updated":"2024-02-08T04:39:01.490127+00:00"}