ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学位論文
  2. 博士論文(医学)

Clinical trial of new methods for identifying lung intersegmental borders using infrared thoracoscopy with indocyanine green: comparative analysis of 2- and 1-wavelength methods

https://kagawa-u.repo.nii.ac.jp/records/187
https://kagawa-u.repo.nii.ac.jp/records/187
68d9c062-000e-4fc5-90e5-bcad9ba6a2a6
名前 / ファイル ライセンス アクション
Med_A572_abstract.pdf 内容の要旨 (346.6 kB)
Med_A572_rusult.pdf 審査の結果の要旨 (392.8 kB)
Item type 学位論文 / Thesis or Dissertation(1)
公開日 2013-06-25
タイトル
タイトル Clinical trial of new methods for identifying lung intersegmental borders using infrared thoracoscopy with indocyanine green: comparative analysis of 2- and 1-wavelength methods
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_db06
資源タイプ doctoral thesis
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 笠井, 由隆

× 笠井, 由隆

en Kasai, Yoshitaka

ja 笠井, 由隆

ja-Kana カサイ, ヨシタカ


Search repository
抄録
内容記述タイプ Abstract
内容記述 OBJECTIVES
Infrared thoracoscopy is a new method of identifying lung intersegmental borders. This study compared the efficacy of 2- and 1-wavelength infrared thoracoscopy.
言語 en
抄録
内容記述タイプ Abstract
内容記述 METHODS
A total of 30 consecutive patients who underwent segmentectomy were evaluated by these methods (2-wavelength method, 10 patients; 1-wavelength method, 20 patients). We ligated the dominant pulmonary artery and then observed the lung using an infrared thoracoscope after indocyanine green (ICG) intravenous injection. The 2-wavelength infrared thoracoscope irradiation and detection were conducted at 940 and 805 nm, respectively, and the images were projected based on the difference of the two reflected wavelengths. ICG absorbs 805 nm wavelength light, and the ICG distribution area appears blue against a white background. On the other hand, the 1-wavelength infrared thoracoscope irradiation and detection were conducted at 780 and 830 nm, respectively. The area stained with ICG shows fluorescence.
言語 en
抄録
内容記述タイプ Abstract
内容記述 RESULTS
In the 2-wavelength method, 3.0 mg/kg of ICG was administered, and a well-defined white-to-blue border was observed in 9 of 10 patients. The staining duration was 220 (interquartile range, 187–251) s. In the 1-wavelength method, 0.5 mg/kg of ICG was administered, and a well-defined border between areas with or without fluorescence was observed in 19 of 20 patients. The staining duration was 370 (interquartile range, 296–440) s, which was significantly longer than the staining duration with the 2-wavelength method (P = 0.0001).
言語 en
抄録
内容記述タイプ Abstract
内容記述 CONCLUSIONS
Infrared thoracoscopy is useful for detection of intersegmental borders. The dose of ICG for the 1-wavelength method was less than that for 2-wavelength method, and the duration of staining was longer.
言語 en
学位名
言語 ja
学位名 博士(医学)
学位授与機関
識別子Scheme kakenhi
識別子 16201
言語 ja
機関名 香川大学
言語 en
機関名 Kagawa University
学位授与年月日
学位授与年月日 2013-06-25
学位授与番号
学位授与番号 甲第572号
PubMed番号
識別子タイプ PMID
関連識別子 23616482
関連サイト
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1093/ejcts/ezt168
キーワード
言語 en
主題Scheme Other
主題 Infrared thoracoscopy
キーワード
言語 en
主題Scheme Other
主題 Indocyanine green
キーワード
言語 en
主題Scheme Other
主題 Lung segmentectomy
KEID
27455
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 12:11:15.872144
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3