ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学位論文
  2. 博士論文(医学)

Efficacy and safety of over-the-scope clip : including complications after endos

https://kagawa-u.repo.nii.ac.jp/records/380
https://kagawa-u.repo.nii.ac.jp/records/380
d1c9d161-9e6d-427d-855d-e4c00ec02294
名前 / ファイル ライセンス アクション
Med_A626.pdf 本文 (5.7 MB)
license.icon
Med_A626_abstract.pdf 内容の要旨 (640.6 kB)
Med_A626_result.pdf 審査の結果の要旨 (637.1 kB)
Item type 学位論文 / Thesis or Dissertation(1)
公開日 2019-07-12
タイトル
タイトル Efficacy and safety of over-the-scope clip : including complications after endos
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_db06
資源タイプ doctoral thesis
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
著者 西山, 典子

× 西山, 典子

en Nishiyama, Noriko

ja 西山, 典子

ja-Kana ニシヤマ, ノリコ


Search repository
抄録
内容記述タイプ Abstract
内容記述 AIM: To retrospectively review the results of over-the-scope clip (OTSC) use in our hospital and to examine the feasibility of using the OTSC to treat perforations after endoscopic submucosal dissection (ESD).
言語 en
抄録
内容記述タイプ Abstract
内容記述 METHODS: We enrolled 23 patients who presented with gastrointestinal (GI) bleeding, fistulae and perforations and were treated with OTSCs (Ovesco Endoscopy GmbH, Tuebingen, Germany) between November 2011 and September 2012. Maximum lesion size was defined as lesion diameter. The number of OTSCs to be used per patient was not decided until the lesion was completely closed. We used a twin grasper (Ovesco Endoscopy GmbH, Tuebingen, Germany) as a grasping device for all the patients. A 9 mm OTSC was chosen for use in the esophagus and colon, and a 10 mm device was used for the stomach, duodenum and rectum. The overall success rate and complications were evaluated, with a particular emphasis on patients who had undergone ESD due to adenocarcinoma. In technical successful cases we included not only complete closing by using OTSCs, but also partial closing where complete closure with OTSCs is almost difficult. In overall clinical successful cases we included only complete closing by using only OTSCs perfectly. All the OTSCs were placed by 2 experienced endoscopists. The sites closed after ESD included not only the perforation site but also all defective ulcers sites.
言語 en
抄録
内容記述タイプ Abstract
内容記述 RESULTS: A total of 23 patients [mean age 77 years (range 64-98 years)] underwent OTSC placement during the study period. The indications for OTSC placement were GI bleeding (n = 9), perforation (n = 10), fistula (n = 4) and the prevention of post-ESD duodenal artificial ulcer perforation (n = 1). One patient had a perforation caused by a glycerin enema, after which a fistula formed. Lesion closure using the OTSC alone was successful in 19 out of 23 patients, and overall success rate was 82.6%. A large lesion size (greater than 20 mm) and a delayed diagnosis (more than 1 wk) were the major contributing factors for the overall unsuccessful clinical cases. The location of the unsuccessful lesion was in the stomach. The median operation time in the successful cases was 18 min, and the average observation time was 67 d. During the observation period, none of the patients experienced any complications associated with OTSC placement. In addition, we successfully used the OTSC to close the perforation site after ESD in 6 patients. This was a single-center, retrospective study with a small sample size.
言語 en
抄録
内容記述タイプ Abstract
内容記述 CONCLUSION: The OTSC is effective for treating GI bleeding, fistulae as well as perforations, and the OTSC technique proofed effective treatment for perforation after ESD.
言語 en
学位名
言語 ja
学位名 博士(医学)
学位授与機関
識別子Scheme kakenhi
識別子 16201
言語 ja
機関名 香川大学
言語 en
機関名 Kagawa University
学位授与年月日
学位授与年月日 2016-03-24
学位授与番号
学位授与番号 甲第626号
権利
言語 en
権利情報 Copyright ©2013 Baishideng Publishing Group Co., Limited. All rights reserved.
権利
言語 en
権利情報 Copyright © The author(s) 1995-2020.
権利
言語 en
権利情報Resource https://creativecommons.org/licenses/by-nc/4.0/
権利情報 Articles published by this open-access journal are distributed under the terms of the Creative Commons Attribution-Noncommercial (CC BY-NC 4.0) License, which permits use, distribution, and reproduction in any medium, provided the original work is properly cited, the use is non commercial and is otherwise in compliance with the license.
論文ID(NAID)
識別子タイプ NAID
関連識別子 500001356440
PubMed番号
識別子タイプ PMID
関連識別子 23687412
関連サイト
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.3748/wjg.v19.i18.2752
関連サイト
関連タイプ isIdenticalTo
識別子タイプ URI
関連識別子 https://dl.ndl.go.jp/pid/11337530
関連サイト
関連タイプ hasVersion
識別子タイプ URI
関連識別子 http://www.ncbi.nlm.nih.gov/pmc/articles/pmc3653149/
著者版フラグ
出版タイプ P
出版タイプResource http://purl.org/coar/version/c_fa2ee174bc00049f
キーワード
言語 en
主題Scheme Other
主題 Over-the-scope clip
キーワード
言語 en
主題Scheme Other
主題 Gastrointestinal bleeding
キーワード
言語 en
主題Scheme Other
主題 Endoscopic submucosal dissection complications
キーワード
言語 en
主題Scheme Other
主題 Gastrointestinal fistulae
キーワード
言語 en
主題Scheme Other
主題 Gastrointestinal perforation
KEID
28744
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 12:15:24.378270
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3